D. The using environment of air purification device

1.   In the process of air processing component use, the air flow rate shall be less than air processing rate.

2.   In the process of air processing component use, pressure shall be less than 1.0 MPa.

3.   Please don’t use the air purification device in water or in the environment of water vapor or the environment surrounded with water.

4.   Please don’t use the air purification device in direct sunlight

5.   Please do not use the air purification device in the workplace surrounded by heat source or radiation

Experience shows that above factors has great influence on resin cup. When use it in new system and new pipe line, please fully confirm the environment.

E. Adjustment

About the relief valve

1.  Set the pressure after confirmation of input and output pressure. If user turns the hand wheel too much, it can cause damage to internal parts.

2.   Turning the hand wheel clockwise to increase output pressure, counterclockwise to lower pressure.

3.   Check input pressure before pressure setting.

4.   Output pressure should be less than 85% of input pressure..

The company's products have been adjusted effectively and correctly before delivery. When it is not essential to set the pressure, please keep the settings untouched.

F. Maintenance

Users should carry on maintenance in accordance with the manual. Improper operation will lead to failure or damage to pneumatic components and devices.

1.   Maintenance work

It is very dangerous to misuse compressed air. Please carry on filter cartridge replacement and other maintenance work after the user has full experience and knowledge about pneumatic components.

2.   Before repair or maintenance, the user must cut off the power and stop air supply, and confirm the residual pressure equals the atmospheric pressure in the pipe line.

3.   Regularly inspect the air filter, filter regulator, oil mist device to check whether there are cracks, scars and other defects on the standard resin cup and the oil window. If you find above phenomenon, please contact Nano to replace in time.

4.   Regularly inspect the air filter, reducing valve, oil mist device to check whether there is pollution on the standard resin cup and the oil window.

If it is dirty, please contact Nano to replace in time.

Please clean with neutral detergent. If using steam, please do not spray directly on the surface. (The highest using temperature is 60 ℃)


Please inform us if any questions or advice

Email:overseas@cmm-nano.com

Feedback
Your comments are welcome!
For more information about our brand and products, please feel free to contact us!
Please enter your email address:
Contact us
Address: NO.55, Gongye No.2 Road, Xi'an National Civil Aerospace Base, Xi'an City, Shaanxi Province, China
Tel: +862981538937
Fax: +862989233633
E-mail: overseas@cmm-nano.com
Copyright © Nano (Xi'an) Metrology Co.,Ltd All rights reserved.